We are bringing forth a wide assortment of Laboratory Instruments that are used for regulating pressure, level and flow in gas & liquid measurements. Our vendors are renowned manufacturers of these instruments who manufacture these instruments in strict adherence with set industrial norms and standards. These instruments are highly efficient in performance and are thus highly demanded nationwide. Offered laboratory instruments are made available in market by us. We also provide timely door-step delivery of these products for our valued patrons. We are the Leader in Service, Rental, Repair, Calibration and Buy Back Exchange Offers of all Instruments.
We are reliable distributor engaged in offering patrons Digital Viscometer of excellent quality. These meters are widely used in sugar and paper industries. We procure these meters from well-established manufacturers who fabricate these meters under the guidance of skilled professionals having deep and thorough knowledge of the subject. These meters are highly reliable in performance and thus are widely demanded countrywide. Customers can avail these meters from us in bulk quantities ensuring excellent quality in each product.
Features:
Easy to use
Accurate results
Low maintenance
Reliable
Smart-functions
Digital Viscometer Include:
Optional Accessories:
Applications:
LV Series – Low Viscosity:
DV-E Viscometer:
MODEL | MIN | MAX | RPM | No of increments |
LVDV-E | 1 | 2 mm | 0.3-100 | 18 |
RVDV-E | 100 | 13 mm | 0.3-100 | 18 |
HADV-E | 200 | 26 mm | 0.3-100 | 18 |
HBDV-E | 800 | 104 mm | 0.3-100 | 18 |
| Range | 0. 0 to 10. 0 mg/l |
| Resolution | 0. 1 mg/l |
| Accuracy | ±0. 2 mg/l ±3% of reading |
| Light source | Led 470 nm |
| Light life | Life of the instrument |
| Light detection | Silicon photocell |
| Battery type/life | 1 x 9 V/approx. 40 hours of continuous use; auto-off after 10 minutes of non use |
| Environment | 0° to 50° C (32° to 122° F); rh max 95% non-condensing |
| Dimensions | 180 x 83 x 46 mm (7. 1 x 3. 3 x 1. 8") |
| Weight | 290 g (10 oz) |
| Method | Modified winker method. The reaction between dissolved oxygen and the reagent causes a yellow tint in the sample |
Carving a special niche for ourselves in the market, we are involved in providing a wide range of Portable Dissolved Oxygen Meter. Offered product is qualitative and acclaimed by the clients for its high operational accuracy. Moreover, client can get this product at reasonable price range.
Specifications:
Calibration: Manual on 2 Points (Zero and Slope)
3½ LCD Display with Symbol
Probe: MA840 (Included)
Range: 0.0~19.9 mg/l
Resolution: 0.1 mg/L
Accuracy: +1.5% Full Scale
Temperature compensation: Automatic from 0~30º C
Salient Features | ||||||||||||||||||||||||||||||||||||||||||||||||
|
Additional Information:
We are suppliers of Mastic Hardness Tester For Bitumen For determining the hardness number of Mastic Asphalt for flooring. It consist of an internally insulated cabinet to the base of which is fitted a water bath having two taps. The bath is heated by an immersion heater and the temperature is controlled with the thermostat at 35° +/- 0.5° C. A 6.5mm dia pin is loaded on the specimen by means of a lever to give a 31.7 Kg weight. A dial gauge
Specifications:
Additional Information:
| Stainless steel inner chamber | |
| Four square semicircle transition, convenient to clean | |
| Micro-computer control system; LCD display with functions of time setting, parameter memorizing and power reset recovering | |
| CFC-free refrigeration and gentle breeze circulation | |
| Double door seal, tempered glass, silicon rubber seal, Inner & Outer door with magnetic rubber seal. | |
| Inner chamber with light for convenient observation |
Model | VTBI-150 |
Make | V-TECH |
Temperature Range | 0 - 65oC |
Temperature Resolution | 0.1oC |
Temperature Uniformity | + 0.5oC |
Working temperature | 5oC to 30oC |
Timer | 1-9999 min |
Refrigerant | R134A |
Power Wattage | 500 W |
Inner dimension (mm) WxDxH | 500 x 400 x 750 |
Outer dimension (mm) WxDxH | 640 x 620 x 1270 |
Load per rack | 2 / 15kg |
Power Supply | 220 V / 50 Hz |
Gross Weight | 97 kg |
Additional Information:
| Range | 0.0 to 199.9 ms/cm |
| Accuracy | ±2% F.S. (excluding probe error) |
| Calibration | Manual, 2 point, with offset and slope trimmers |
| Temperature Compensation | Fixed or automatic from 0 to 50° C (32 to 122° F) with ß=2%/°C |
| Output | 4-20 mA, not isolated, max 500 Ohm |
| Probe | HI 7635 (in-line application) or HI 7638 |
| Protection | IP 65 |
| Power Supply | 12-30 VDC |
| Environment | 0 to 50° C (32 to 122° F); RH max 95% non-condensing |
| Dimensions | 165 x 110 x 90 mm (6.5 x 4.3 x 3.5") |
| Weight | 1 kg (2.2 lb.) |
Additional Information:
|
Model | VTOV - 43 | VTOV - 70 | LMOV - 136 |
|
Make | V-TECH | |||
Temperature Range ºC | Ambient + 10 to 250 ºC | |||
Temperature Resolution | 0.1ºC | |||
Temperature Uniformity | +1.0ºC | |||
Inner Chamber Dim. (SS) WxDxH (mm) | 350 x 350 x 350 | 450 x 350 x 450 | 550 x 450 x 550 |
|
Outer Dim.(mm) WxDxH | 650 x 510 x 525 | 750 x 510 x 625 | 850 x 600 x 725 |
|
Heating Power | 1.2KW | 1.6KW | 2KW |
|
Load per rack | 2 / 15 kg per rack | |||
Power supply | 220V / 50Hz | |||
Gross Weight | 56kg | 66kg | 79kg |
|
Additional Information:
Fatty Acid Tester we manufacture holds a huge demand in Global market. Sample free fatty acids in the edible oil is nothing but the acidity of the oil (pH of the oil). Free fatty acid having free H+ ion is responsible for shifting the pH value in the lower side. This pH of the edible oil is treated by pH indicator; the color shift is measured by spectrophotometer. The absorption of the light is proportional to the concentration of the free fatty acid in the edible oil. , It is possible to carry out a test using micro-quantities of sample and can be applied even to fat substances that have a difficult extraction process.
Salient Features
Based on E.M.F.C Technology | |||||||||||||||||||||||||||||||||||||||
Halogen Heating System | |||||||||||||||||||||||||||||||||||||||
Temprature Range upto 200°C | |||||||||||||||||||||||||||||||||||||||
RS232C Interface | |||||||||||||||||||||||||||||||||||||||
The Mode for testing Automatic, Timing, Manual | |||||||||||||||||||||||||||||||||||||||
| Moisture Balance based on E.M.F.C sensor and its working on the principle of thermal force, from the percentage between the weight when the sample is dry and the weight when the sample is moist. we can get the value of moisture.
|
Additional Information:
Based on E.M.F.C Technology | |
A built in under hook for below weighing | |
Density measurement (Optional) | |
RS232C Interface | |
Tare range upto max. Capacity of the Balance | |
High Resolution, Quick Weighting, Accurate Result | |
Automatic External Calibration | |
Multifunction Weighting Units | |
S.S Weighing Pan, Level Indicator, Adjustable Fit | |
Counting Weighting Mode |
MODEL | VTHPB 220 | VTHPB 510 | VTHPB 1000H |
SPECIFICATION | Capacity | 220 g | 510 g | 1000 g |
Readability | 0.001 g (1mg) | |||
Repeatability (±) | 0.001 g | |||
Linearity (±) | 0.002 g | |||
Make | V-TECH | |||
Pan Size | 90 mm Ø | 150 mm Ø | ||
Display | VFD (Vacuum Fluorescent Display) | |||
Response Time | 3-4 Sec | |||
Calibration | Automatic External | |||
Tare Range | Full | |||
Operating Temperature | 10°C to 40°C | |||
Interface | RS232C | |||
Power Supply | AC 220V / 50 - 60 Hz | |||
Dimension (LxWxH) mm | 530 x 435 x 490 | |||
Weight | 10 Kg | |||
Additional Information:
Salient Features
Microprocessor Control | |
| The MS-300 and MS-400 hot plate magnetic stirrer is operated by a digital control CPU. The CPU regulates the heating up to 300 °C and 400 °C in the respective models & Model MS 200 is without Hot Plate |
Digital Speed Control | |
| Stirring speed is also controlled by the CPU from the keypad while the stirring speed is indicated on the bar graph. |
Programmable | |
| Operator can setup the objective temperature, hold temperature, stirring time and speed |
Automatic Temperature Control | |
| Connect the temperature probe and place into glass container being stirred to measure and maintain the object temperature Accuracy is +1 °C. |
Product Included | |
| Stir Bar, Temperature Probe (For MS300/400) |
| ||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||
Additional Information:
Salient Features Fully Automatic microprocessor control | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Stainless Steel construction | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Continuous Ice Flakes Output | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CFC free compressor | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Low water level Indication | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Overload protection | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Noiseless operation | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Compact Design and low maintenance.
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Additional Information:
Salient Features
Quick and Fast Reading | |||||||||||||||||||||||
Big LCD Display | |||||||||||||||||||||||
Calculate initial and final melting points automatically | |||||||||||||||||||||||
Measures three samples at the same time | |||||||||||||||||||||||
Detection through Photo Electric | |||||||||||||||||||||||
Direct display of melting curve on LCD | |||||||||||||||||||||||
RS 232 interface | |||||||||||||||||||||||
| |||||||||||||||||||||||
| |||||||||||||||||||||||
Additional Information:
Concrete Moulds are easily cast by using a tamping bar or a vibrating table. However air trapped in cement mortar paste can not be thus removed while casting cement mortar moulds. Easy method is to impart greater vibration of lesser amplitude to the mould while casting. This is achieved in a Vibrating Machine. Vibrating Machine is used for the preparation of mortar cubes for the determination of compression strength of ordinary and rapid hardening Portland cement, low heat Portland cement, Portland blast furnace cement and high alumina cements.
Specifications:
Additional Information:
Salient Features
• Can measure 0.5~3 µl samples | |||||||||||||||||||||||||||
• Quick measure without pre-warm | |||||||||||||||||||||||||||
• There's no need to dilute the samples | |||||||||||||||||||||||||||
• Quick Scan, curve in only 0.2 seconds | |||||||||||||||||||||||||||
• Long life lamps. more than 2000 hours | |||||||||||||||||||||||||||
• Software comes standard with the instrument
| |||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||
|
Additional Information:
Nitrogen Gas Generator Nitrogen Gas & Air Generator
MODEL | VTGG-300N2 | VTGG-500N2 | VTGG-300N2A | VTGG-500NA2 | |
Type Of Generator | Nitrogen Gas Generator | Nitrogen Gas & Air Generator | |||
Make | V-TECH | ||||
Purity | 99.999% | ||||
Output Flow (N2) ( Max) | 300ml/min | 500ml/min | 300ml/min | 500ml/min | |
Output Flow (Air) | N/A | N/A | 2L /min | 5L/min | |
Output Pressure | 0.4Mpa | ||||
Working temperature | 0– 40oC | ||||
Power Wattage | 150 W | 350 W | |||
Gen. Dim. LxWxH (mm) | 360 x 190 x 380 | ||||
Power supply | 220 / 50 Hz | ||||
Gross Weight | 16 kg | 30 kg | |||
Additional Information:
FEATURES |
|
* O2 ( Air oxygen ) and Temp. ( Air Temp. ) measurement. |
* O2 measurement range : 0 to 30.0 % x 0.1 %. |
* Temp. measurement range : 0 to 50 ℃, ℃/. |
* O2 Buzzer warning : If the measurement value %O2, the buzzer will sound for warning. |
* Galvanic cell type for O2 sensor. |
* High reliability Oxygen sensor, not be affected by acidic gases like CO2. |
* Oxygen sensor with temperature compensated. |
* Data hold, to freeze the desired reading value. |
* Auto power off saves battery life. |
* Operates from DC 1.5V ( UM4/AAA ) x 4 PCs batteries. |
* Microprocessor circuit ensure high accuracy, and also and also provides special functions and features. |
* Durable and compact ABS-plastic housing. |
* Application : O2 monitor/dectors, Food industrial ( Refrigerator, Vegetable factory ), Bio-Technology ( Oxygen incubator, Anaerobic cultivator ), Security system ( Air conditioner and Oxygen shortage alarm system, Fire alarm system ), Fuel cell system. |
GENERAL SPECIFICATIONS | ||
Display | LCD size : 28 mm x 19 mm. | |
Measurement | O2 ( Air oxygen ) | |
| ||
Sensor | Oxygen | Galvanic cell type |
| Temperature | Thermistor |
Circuit | Custom one-chip of microprocessor LSI Circuit | |
Data Hold | Freeze the display reading. | |
Sampling Time | Approx. 1 second. | |
Power off | Auto shut off saves battery life. | |
Operating Temperature | 0 to 50 ℃. | |
Operating Humidity | Less than 80% R.H. | |
Power Supply | DC 1.5 V battery ( UM4/AAA ) x 4 PCs. | |
Power Current | Approx. DC 4.0 mA | |
Weight | 194 g/ 0.43 LB. |
Dimension | 180 x 40 x 40 mm (7.1" x 1.6" x 1.6") |
Accessories | Instruction manual 1 PC |
Soft carrying case ( CA-52A ) 1 PC | |
Application | * O2 monitor/dectors. |
* Food industrial : Refrigerator, Vegetable factory | |
* Bio-Technology : Oxygen incubator, Anaerobic cultivator | |
* Security system : Air conditioner and Oxygen shortage alarm system, Fire alarm system | |
* Fuel cell system. |
| Range (PH) | 0.00 to 14.00 PH |
| Resolution (PH) | 0.01 PH |
| Accuracy (PH) | ±0.2 PH |
| Calibration | Manual, 2 points |
| Electrode | Not included |
| Battery Type/Life | 2 x 1.5 V/approx. 3000 hours of continuous use |
| Environment | 0° to 50° C (32° to 122° F); RH max 95% |
| Dimensions | 66 x 50 x 25 mm (2.6 x 2.0 x 1.0") - without probe |
| Weight | 50 g (1.8 oz) |
Specifications:
| PH Range | 0.00 - 14.00 PH |
| PH Resolution | 0.01 PH |
| PH Control | Adjustable set point in range 5.20 - 10.00 PH |
| ORP Range | +/- 1999 mV ORP |
| ORP Resolution | +/- 1 mV ORP |
| ORP Control | Adjustable set point in range 200 - 600 mV (can be Modified) |
| PH 115 V AC outlet | Powered when actual pH reading |
| ORP 115 V AC outlet | Powered when actual ORP reading is Below the Set Point |
| Display | pH LCD/H=1 /2" (12.5 mm), ORP LCD/H=3/8" (7.7 mm) |
| Dimensions | 6.2 x 6.7 x 2.2" (W x H x D) |
| Weight | 1.7 Lbs./0.8 kg |
| Power Consumption | 115 V AC/60 Hz/0.25 Amp |
| PH and ORP outlets | 115 V AC/60 Hz/Maximum 5 Amp. Per outlet |
| Range | 0.00 to 9.99; 10.0 to 99.9 and 100 to 1000 NTU |
| Range Selection | Automatic |
| Resolution | 0.01 NTU from 0.00 to 9.99 NTU; 0.1 NTU from 10.0 to 99.9 NTU;1 NTU from 100 to 1000 NTU |
| Accuracy | ±2% of reading plus 0.02 NTU |
| Repeatability | ±1% of reading or 0.02 NTU, whichever is greater |
| Stray Light | < 0.02 NTU |
| Typical EMC Deviation | ±0.05 NTU |
| Light Detection | Silicon Photocell |
| Method | Ratio Nephelometric Method (90°), ratio of scattered and transmitted light;Adaptation of the USEPA Method 180.1 and Standard Method 2130 B. |
| Measuring mode | Normal, Average, Continuous |
| Turbidity Standards | 1, 10, 100 and 750 NTU |
| Calibration | Two, three or four-point calibration |
| Light Source | Tungsten filament lamp |
| Lamp life | Greater than 100,000 readings |
| Range | 0.00 to 50.00 FTU; 50 to 1000 FTU | |
| Resolution | 0.01 FTU; 1 FTU | |
| Accuracy | ±0.5 FTU or 5% of reading (whichever is greater) | |
| Calibration | 3 points (0 FTU, 10 FTU, 500 FTU) | |
| Light Source | infrared LED | |
| Light Life | Life of the instrument | |
| Light Detection | Silicon Photocell | |
| Power Supply | 12 VDC adapter (included) | |
| Environment | 0 to 50° C (32 to 122 °F); RH max 95% non-condensing | |
| Dimensions | 230 x 170 x 70 mm (9.0 x 6.7 x 2.8") | |
| Weight | 600 g (1.3 lb.) |
Rebound Hammer is a device for measuring elastic properties/strength of concrete/rock and helps in testing mainly surface hardness and penetration resistance properties.
Specification:
· Usage: Concrete Rebound Hammer
· Testing instrument: Concrete Rebound Hammer
· Color : Customized
Features:
Additional Information:
| Range (PSU) | 0 to 50 |
| Range (Ppt) | 0 to 150 |
| Range {Specific Gravity (20/20)} | 1.000 to 1.114 |
| Range (Temp) | 0° to 80° C (32° to 176° F) |
| Resolution (PSU) | 1 |
| Resolution (Ppt) | 1 |
| Resolution {Specific Gravity (20/20)} | 0.001 |
| Resolution (Temp) | ±0.1° C (0.1° F) |
| Accuracy (@20° C) (PSU) | ±2 |
| Accuracy (@20° C) (Ppt) | ±2 |
| Accuracy (@20° C) {Specific Gravity (20/20)} | ±0.002 |
| Accuracy (@20° C) (Temp) | ±0.3° C (0.5° F) |
| Temperature Compensation | Automatic between 10° and 40° C (50° to 104° F) |
| Measurement Time | Approximately 1.5 seconds |
| Minimum Sample Volume | 100 L (to cover prism totally) |
| Light Source | Yellow LED |
| Sample Cell | Stainless steel ring and flint glass prism |
| Auto-off | After 3 minutes of non-use |
| Enclosure Rating | IP 65 |
| Battery Type/Battery Life | 9 V/Approx 5000 readings |
| Dimensions/Weight | 192 x 102 x 67 mm (7.6 x 4 x 2.6)/420 g |
Additional Information:
Additional Information:
'V-TECH' Make Tubular Impact Tester allows both the failure point to be measured. It can be used with paints, Varnishes, plastic coating, laminations and sheet material. A sample clamp securely hold the test piece, Impact can be varied by adjusting weights or heights.
Specifications:
Additional Information:
Additional Information:
Salient Features
Stainless steel Inner chamber & Outer body electro static spraying exterior | |
Micro-computer temperature controller with function of timing and over-temperature protection | |
High brightness digital tube display and soft touch keys for parameter settings | |
Tightness of door is adjustable | |
Double layered tempered glass anti-explosion door; silicon rubber seal provides a high vacuum degree and keep longer time |
Specification
Model | VTVO-24 | VTVO-52 |
Make | V-TECH | |
Temperature Range ºC | Ambient + 10- 250ºC | |
Temperature Resolution ºC | 0.1ºC | |
Temperature Uniformity | + 1% | |
Inner Dimension (mm) WxDxH | 300x300x270 | 415x370x340 |
Outer Dimension (mm) WxDxH | 480x480x605 | 560x540x680 |
Power Wattage | 800 W | 1400 W |
Vacuum degree | 220V / 50Hz | |
Gross Weight | 52 kg | 92kg |
Additional Information:
| Range | pH | 0.00 to 14.00 pH |
| Resolution | 0.01 pH | |
| Accuracy | pH | ±0.01 pH |
| Flow Rate | 13.3, 11.7, 10.1, 9.0, 7.8 (LPH) | |
| Input Impedance | 1012 Ohm | |
| Dosage | proportional, acid or base, user selectable | |
| Calibration | offset: ±1 pH with trimmer; slope: 85 to 115% with trimmer | |
| Recorder Output | 4-20 mA (isolated) | |
| Dosing Contact | 1 isolated contact, 2A, Max. 240 V, resistive load, 1,000,000 strokes | |
| Alarm Contact | 1 isolated contact, 2A, Max. 240 V, resistive load, 1,000,000 strokes | |
| Power Supply | See Chart | |
| Environment | 0 to 50° C (32 to 122° F); RH max 95% non-condensing | |
| Dimensions | 181 x 221 x 142 mm (7.1 x 8.7 x 5.6") | |
| Weight | 5 kg (11 lb.) |
| Range | 0.00 to 14.00 pH / 4 to 20 mA, -2.00 to 16.00 pH / 4-20 mA |
| Resolution | 0.01 mA / 0.01 pH |
| Accuracy | ±0.02 mA / ±0.02 pH |
| Calibration | Offset: ±2.2 mA / ±2 pH; slope: ±0.5 mA / 86 to 116% |
| Temperature Compensation | Fixed or Automatic from 0 to 100° C (32 to 212° F) with HI 76608 probe |
| Input Impedance | 1012 Ohm |
| Output | 4-20 mA (isolated) |
| Temperature Probe | HI 76608 |
| Protection | IP 65 |
| Power Supply | 18-30 VDC |
| Load | Max 500 Ohm |
| Environment | 0 to 50° C (32 to 122° F); RH max 95% non-condensing |
| Dimensions | 165 x 110 x 90 mm (6.5 x 4.3 x 3.5") |
| Weight | 1 kg (2.2 lb.) |
Additional Information:
Showcase Gallery
© Nunes Instruments. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited