Owing to our vast experience in this domain, we have been able to bring forth a commendable range of Digital ELCB Tester to our clients. We are committed to bring quality in the offered product and for this, sourced it from the leading vendors.
Special Features:
2 Lines x 16 Characters L.C.D
Very low consumption
Disconnection phase polarity is shown on L.C.D. display
Auto-off and Off override
Polarity trip indicator (negative or positive phase)
Wiring polarity indicator
EN 61010-1 CAT III 240 V
Microprocessor controlled
Menu Driven
Accurate digital readout is fitted to give information of disconnection time
Automatic data hold function
Zero crossing circuitry allow testing at 0° or 180°
Specifications:
Current Settings are 3 mA, 5 mA, 7 mA, 10 mA, 15 mA, 20 mA, 30 mA, 35 mA, 50 mA, 100 mA, 125 mA, 150 mA, 175 mA, 250 mA, 300 mA, 375 mA & 500 mA
Current Selection: Rotary switch selector
Phase Polarity Trip Indicator: Yes (LCD) Referenced to Earth
Voltmeter (L-E): 20 V AC - 280 V AC
Timer Resolution: 1 ms (max time = 2.999 s)
Timer Accuracy: +/- 2% +/- 2 ms
Current Accuracy: +/- 5% +/-1 mA
Voltmeter Resolution: 1 V AC
Voltmeter Accuracy:+/- 2% +/- 1 V AC
Operating Temperature: -5° C to 45° C
Storage Temperature: -10° C to 85° C
Power Source:1.5 V (AA) x 8 batteries
Bat OK Led = V bat > 7.5 V
Dimensions: 170 (L) x 165 (W) x 92 (D) mm
Weight: Approx. 1020 g (battery included)
Phase Start Selection: 0° and 180°
Over-temperature Protection: Yes (3 sensors)
Wiring Correctness Indication: Yes (LCD's)
Trip Indicator: Yes (LCD)
Accessories:
Test leads (TEL-1812)
Shoulder belt (BET-1800)
Instruction manual
Batteries
Operating Voltage (L-E) 50 Hz or 60 Hz:
1812EL-A: 240 V AC
1812EL-B: 230 V AC
1812EL-C: 220 V AC
1812EL-D: 110 V AC
PID temperature controller |
Cold rolling steel spraying exterior |
Elements embedded in walls of the chamber to provide, high temperature, uniform heating and long service life |
Light-weight insulating brick, fiber cotton are used as thermal |
| ||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||||||||||||||||||||
Additional Information:
Geiger Counter Detects Alpha, Beta, Gamma, and X-rays
Radioactivity is everywhere. It occurs naturally and it can be detected. It can also be deadly.
Monitor 4 features easy-to-read analog meter, red light count, anti-saturation circuitry, and audible indicator- all in hand-held convenience. Great for checking for soft X-ray radiation, and for determining back-ground ionizing radiation (granite, porcelain, solar flares, natural radioactivity, etc.)
Check for radioactive contamination of clothing, food, water or imported goods.
Uses a halogen quenched uncompensated Geiger Mueller tube with a thin mica window. Detects alpha down to 2.5 MeV, 80+% efficiency at 3.6 MeV. Detects beta at 50 keV with 35% efficiency, and 150 keV with 75% efficiency. Detects gamma and X-ray down to 10 keV. Range of 0 - 50 mR/hr and 0-500 µSv/hr. Requires 9V battery. 1-year warrantee. Made in USA.
Additional Information:
Thermal Instruments Calibration Service offered are offered at IS/ISO accredited testing and calibration laboratory to assure of high calibration accuracy.
Features:
Lab facilities well equipped for achieving high precision thermal calibration
Support for calibration ranging from -80 °C to 1200 °C
Specifications:
Offering support for Digital thermometer readout/probe system calibration, fixed-point cell calibration, hygrometer, humidity chamber, temperature bath
Offering temperature calibration for hygrometer, humidity chamber, thermocouple, oven / furnace, temperature bath
Also offering support for temperature controller / indicator, liquid in glass thermometer, BOD incubator, deep freezer, hot plate
Thermometer Calibration Services offered are handled using modern lab facilities to assure of accurate testing reliability.
Features:
Support services involving calibration of determining recertification of thermometers
Services offered as per regulatory agencies' guidelines and policies
Specifications:
Services offered based on good laboratory and manufacturing practices
Recertification program comprise complete visual inspection for any physical damage
Thermometer readings compared against NIST standards in high precision calibration baths
Each temperature recorded to 1/10th of a scale division
Calibration report generated feature pertinent information including correction factors for each test point
Certification procedures performed in accordance with defined industry guidelines