Pioneers in the industry, we offer single beam visible spectrophotometer sf00000866, uv vis double beam spectrophotometer sf00000867, double beam microprocessor uv vis spectrophotometer sf00000868, single beam uv vis microprocessor spectrophotometer sf00000869, double beam microprocessor uv vis spectrophotometer sf00000871 and electronic analytical balances sf00003446 from India.
₹ 218400 / Piece Get Latest Price
| Wavelength Range | 325-1100 nm |
| Optical System | Single Beam |
| Mobility | Portable |
| Spectral Bandwidth | 2 nm |
| Brand | V-TECH |
| Model No / Item Code | VT - 722 |
| Wavelength Accuracy | +- 0.5 nm |
| Wavelength Repeatability | +- 0.2 nm |
| Display | Single Beam |
| Usage / Application | Laboratory |
| Dimensions | 56 x 48 x 29 cms |
| Cell Holder | 10 mm |
₹ 189500 / Piece Get Latest Price
| Brand | V-Tech |
| Tube Voltage | 100-240V |
| Features | As per datasheet |
| Color | Grey |
| Insertion Depth | 10 mm |
| Range | 2-15 kg(x 105 pa) |
| Weight | 0.3 kg |
Features
· Suitable for1H and11F nuclei
· FET based marginal Oscillator
· Digital Display of frequency and current
· Clear display of resonance peaks
· Compatible with general purpose CRO
Introduction
Nuclear Magnetic Resonance (NMR) was discovered by Bloch and Purcell in the year 1945. Over the years it has developed into a very useful and powerful tool in solid state physics, chemistry and biology. In medical application this technique, under the name Magnetic Resonance Imaging (MRI) has been developed as an excellent imaging method for clinical diagnosis. In this method use is made of Zeeman interaction of the magnetic dipoles associated with the nucleus when placed in a external magnetic field.
Elementary Magnetic Resonance
An atom whose nucleus has a nulcear spin I will have a magnetic moment as follows
= gnI (1)
where nis nuclear magneton, and g is g-factor. Under the influence of an external static magnetic field (H), these nuclear magnets can orient in distinct directions. Each spin orientation corresponds to a particular energy level given by
E = gnHmj(2)
with mj= -I, -(I-1), ...............(I-1), I
where mjis magnetic quantum number
The splitting of levels will therefore be-
DE = gnH or = hn0 (3)
where n0is the r.f. frequency applied perpendicular to the static magnetic field. Now if the spins are subjected to a purturbation by an oscillating magnetic field with its direction parallel to the static magnetic field and its frequency n1such that the quantum hn1is equal toDE = hn0, we say that there is a resonance between n1and n0. This will induce transition between neighbouring sub levels (mj=I) and in turn will absorb energy from the oscillating field. Thus, at resonance, we get a peak due to the absorption of energy by the system.
Experimental Technique
Nunes Instruments , is in the field of Instrumentation Sales Service & Repairs with 40 years of experience. We provide service & repairs to your old high precision instruments and equipment. We provide cost effective service & Repair to any brand, any make instruments with service warranty. W hy not try once?
Instruments of Any Type, Any Make, Analog/Digital, Any Condition Indian or Imported
₹ 745000 / Piece Get Latest Price
| Spectral Bandwidth | 1 nm |
| Wavelength Accuracy | +-1.0 nm |
| Temperature Range | 15 Degree C to 65 Degree C |
| Time range | 30s to 10 minutes |
| Sampling Speed Around | 50ml /min |
Double Beam Microprocessor UV-VIS Spectrophotometer equipped with a Peltier and Sipper System is a sophisticated analytical instrument designed for precise and accurate measurement of absorbance and transmittance of liquid samples across the ultraviolet (UV) and visible (VIS) spectrum.
Key Features and Components:1. Double Beam Configuration:₹ 179270 / Piece Get Latest Price
| Wavelength Range | 195nm - 1020 nm |
| Optical System | Single Beam |
| Brand | V-Tech |
| Wavelength Accuracy | +/-2nm |
| Photometric Accuracy | +-0.5% T |
| Photometric Repeatability | +- 0.2% T |
| Stray Light | <= 0.3%T @220nm |
| Stability | +/- 0.004 A/h @500nm |
| Weight | 12 kg |
| Display modes | 4 LCD |
| Zero setting | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Repeatability | 1nm |
Technical Parameters:
Model VT-285
Optical system: CT grating monochromator
Wavelength range: 195nm - 1020 nm
Wavelength accuracy: +/-2nm
Spectral bandwidth 2nm
Wavelength repeatability: 1nm
Stray light: <= 0.3%T @220nm
Photometric accuracy: +/- 0.5% T
Photometric repeatability: 0.2%T
Stability: +/- 0.004 A/h @500nm
Work Pattern: T, A, C
Display area: 0-200%T, -0.3 - 3A
Display modes: 4 LCD
Zero setting Automatic
Weight: 12 kg
Nunes Instruments , is in the field of Instrumentation Sales Service & Repairs with 40 years of experience. We provide service & repairs to your old high precision instruments and equipment. We provide cost effective service & Repair to any brand, any make instruments with service warranty. W hy not try once?
Instruments of Any Type, Any Make, Analog/Digital, Any Condition Indian or Imported
₹ 556000 / Piece Get Latest Price
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Spectral Bandwidth | 1 nm |
| Photometric Range | -0.3 to 3.0 A |
| Display | 7-inch color touch screen |
Double Beam Microprocessor UV-VIS Touch Screen Spectrophotometer is a sophisticated analytical instrument used to measure the absorbance and transmittance of liquids and solids over the ultraviolet and visible light spectrum (typically 190 nm to 1100 nm). The instrument is designed for a wide range of applications including pharmaceuticals, biotechnology, environmental testing, and materials science.
Key FeaturesDouble Beam Optics:₹ 22750 / Piece Get Latest Price
| Accuracy | 0.001 gm |
| Display | Text |
| Material | Aluminium |
| Country of Origin | Made in India |
| Capacity | 300 grams (Max) |
| Interface | RS232C |
| Battery Backup | Over 20 hours continuous usage |
| Calibration | External calibration |
The Digital Analytical Balance (P6 Series) is a high-precision weighing instrument designed for laboratory, research, and quality control applications. With a maximum capacity of 300 grams and an impressive readability of 0.001 grams (1 mg), it ensures reliable and accurate measurements for sensitive tasks.
This balance features a user-friendly large LCD display with a backlight for clear visibility in all lighting conditions. Models in the P6 series offer an RS232C interface for data transfer to a printer or PC, making it ideal for documentation and analysis.
Its AC/DC dual power system with a rechargeable battery allows more than 20 hours of continuous operation, ensuring flexibility and portability in various environments.
Key Features1 mg readability with stable, repeatable performance
External calibration ensures measurement accuracy
Auto shut off and low battery alert for energy efficiency
Full tare and auto zero tracking functions for accurate net weight measurement
RS232C interface for easy data export
Durable, large weighing pan supports a wide range of sample sizes
Portable design with long battery backup for field or mobile use
Research laboratories
Pharmaceutical analysis
Chemical testing
Educational institutions
Industrial quality control
₹ 4225000 / Piece Get Latest Price
| Wavelength Range | 190-1100 nm |
| Optical System | Double Beam |
| Mobility | Portable |
| Spectral Bandwidth | 4 nm |
| Country of Origin | Made in India |
| Software Compatibility | UV WinLab (or equivalent analytical software) |
| Application Type | Laboratory Analytical Instrument |
| Portability | Portable Design |
The VT35 Double Beam Portable UV/Vis Spectrophotometer is a high-precision analytical instrument engineered for routine laboratory analysis and quantitative measurement tasks. Inspired by the performance class of the PerkinElmer Lambda-35 series, this instrument delivers reliable optical performance with a wavelength range of 190–1100 nm.
The device features multiple variable bandwidth settings (0.5 nm, 1 nm, 2 nm, and 4 nm), enabling superior measurement control and allowing the user to tailor resolution according to analytical requirements. The system integrates seamlessly with UV WinLab-type software for step-by-step workflow guidance, advanced data processing, and intuitive operation. Designed for portability, the VT35 provides high-quality double-beam performance in a compact, user-friendly form.
Key FeaturesDouble-beam optical design for high stability and accuracy
Wide wavelength range from 190 to 1100 nm
Variable bandwidths (0.5 / 1 / 2 / 4 nm) for flexible measurement resolution
Software-controlled system with advanced data analysis features
Portable and suitable for routine laboratory testing
Ideal for quantitative, qualitative, and kinetic measurements
Reliable performance comparable to high-end laboratory spectrophotometers
Pharmaceutical quality control
Chemical and biochemical analysis
Environmental testing (water, pollutants, etc.)
Academic and research laboratories
Food and beverage analysis
Material science and optical studies
SF Nunes (Nunes Instruments)
Nunes Instruments
11a/1, 11a/2, Sundaram Street
Coimbatore - 641027, Tamil Nadu, India